Вход в систему

Консульство Овалон-2

Навигация

  • strict warning: Non-static method Pagination::getInstance() should not be called statically in /var/www/owalo863/data/www/owalon.com/modules/pagination/pagination.module on line 308.
  • strict warning: Only variables should be assigned by reference in /var/www/owalo863/data/www/owalon.com/modules/pagination/pagination.module on line 308.
  • strict warning: Non-static method Pagination::getInstance() should not be called statically in /var/www/owalo863/data/www/owalon.com/modules/pagination/pagination.module on line 403.
  • strict warning: Only variables should be assigned by reference in /var/www/owalo863/data/www/owalon.com/modules/pagination/pagination.module on line 403.
  • strict warning: Non-static method Pagination::getInstance() should not be called statically in /var/www/owalo863/data/www/owalon.com/modules/pagination/pagination.module on line 345.
  • strict warning: Only variables should be assigned by reference in /var/www/owalo863/data/www/owalon.com/modules/pagination/pagination.module on line 345.

Реактор собранный школьниками из Италии

It is with emotion that we are going to take this step: making available on the internet the construction of ATHANOR. Forgive us for the quality of the image, we hope you’ll understand how much we are running. Send us all your questions and with quick replies we will make us forgive the poor quality of the images.

For some reasons we are not yet fully effective in managing the documentation, but we’re categorizing everything.

PERFORM ONLY BY AT LEAST TWO EXPERTS, WITH THE APPROPRIATE PROTECTIONS UNDER THE SAFETY RECOMMENDATIONS IN LABORATORIES UNDER A CLOSED INTAKE GLASS HOOD WITH HIGH DILUTION OF SMOKE.

GATHER CAREFULLY THE RESIDUALS FOR A SUITABLE WASTE DISPOSAL OF LIQUID AND SOLID

IT IS ABSOLUTELY NOT RECOMMENDED, AND WE ARE NOT RESPONSIBLE FOR IT, TO OPERATE IN THE PRESENCE OF INCIDENTAL SPARKS OR FREE FLAMES BECAUSE OF EXPLOSIVENESS BOTH OF HYDROGEN AND OF DUST IF THE FUNNEL SHOULD DRY INSIDE, NOT PROTECTING THEM ANYMORE IN THE FORM OF MUD.

THE INFRINGING OF THESE RULES AND OF THOSE OF CAUTION TO USE IN THOSE SITUATIONS CONFIGURATES LIABILITIES THAT EXONERATE THE ALLOCATION OF THEM TO US.

WE CARE ABOUT OUR LIABILITY JUST AS MUCH AS WE CARE OF YOUR HEALTH. (INSERT A RED BUTTON SWITCH THAT DISCONNECTS BOTH POLARITIES AND CHECK THE CIRCUIT BREAKER OF THE SYSTEM).

IT IS RECOMMENDED TO SURROUND THE CELL WITH LEAD SHEET, TO PUT A THICK PLEXIGLASS PLATE BETWEEN THE CELL AND A WEBCAM WITH THE WIRE SHIELDED WITH ALUMINUM FOIL, BUILD A WALL OF WATER BY RECTANGULAR CONTAINERS THAT SURROUND THE CELL COMPLETELY, INSERT A GEIGER COUNTER CLEARLY VISIBLE BY THE WEBCAM AND OPERATE IN A REMOTE STATION WITH 6 SQMM SECTION CABLES.

WHOEVER BUILDS AND OPERATES THE DESCRIBED EQUIPMENT IS FULLY RESPONSIBLE EVEN AGAINST DAMAGE TO THIRD PARTIES, EXPRESSLY EXEMPTING THE AUTHORS OF THIS TEXT FROM ANY LIABILITY.

THE SIMPLE IMPLEMENTATION OF EXPERIMENTATION, BOTH AS DESCRIBED HERE OR IN FREE FORM, IS AN ACT OF UNCONDITIONAL ACCEPTANCE OF WHAT IS ADVISED HERE.

WE FORMALLY WARN PERSONS NOT TO OPERATE THE EQUIPMENT IF YOU DON’T HAVE A TECHNICAL DEGREE OR EQUIVALENT EXPERIENCE.

GOOD EXPERIMENTATION, and may you soon achieve yields higher than those detected by us!

IN THE FOLLOWING DESCRIPTION PLEASE REFER TO THE IMAGE

The apparatus, can be easily made and is absolutely not expensive, consisting of a suspended crew with a bar (27) to an external support, and of an open container (15), pyrex, with capacity of 1000 ml, containing a high splashguard (14). The support should allow the easy put on the same axis of the crew.

The container is on a scale (28) with collecting plate (19) of potential drops so they continue to weigh.

The display (20) is protected by drops; on the bottom of the container there is an insulator (23) (between dish and container). The reactor has a cylindrical removable insulation (17).

It is filled with about 900 ml of solution 0.1 – 0.4 molar of potassium carbonate in distilled water.

A set of thermocouples (10) measures the temperature range (which is not uniform).

On the plate, special locks (18) prevent the container to move with the strong action of the plasma.

The anode (8) is made of a stainless steel mesh of the approximate area of 13 sq. cm., interchangeable with grids of different sizes, positively fed from the connector (11) by means of insulated (or isolated?) stainless steel bar. The pyrex tube (9) allows the insulated (or isolated?) leakage of oxygen from the anode, through the outlet (24).

The cathode connector (12) feeds, by means of a stainless steel bar covered with Teflon tube surrounded by heat shrink tubing, the clamp (22) that blocks the bar cathode of tungsten interchangeable of 1.6 mm diameter.

Particular attention must be paid to the implementation of the protection of the terminal from the electrical contact with the conductive solution.

The cap (21) makes access to the screw for clamping the cathode (3) in the terminal.

The ceramic plate (alumina) (4), crossed by the cathode, and ‘glued to the Pyrex funnel (5) by means of high temperature epoxy resin.

On the plate is placed a mixture of tungsten needles (length 3 -5 mm and diameter 0.1 mm) of 2-5 grams and powders, in the form of mud, the grain size between 100 microns and 50 nanometers, in variable proportions, of the weight of g. 1 to 2.

Rambler

Сейчас на сайте

Сейчас на сайте 0 пользователей и 1 гость.